{"id":707,"date":"2025-01-31T09:03:31","date_gmt":"2025-01-31T08:03:31","guid":{"rendered":"https:\/\/www.tb-klade.at\/applications\/kuehlturm-desinfektion\/"},"modified":"2026-08-21T17:08:12","modified_gmt":"2026-08-21T15:08:12","slug":"kuehlturm-desinfektion","status":"publish","type":"page","link":"https:\/\/www.tb-klade.at\/en\/applications\/kuehlturm-desinfektion\/","title":{"rendered":"Biocides in evaporative cooling systems"},"content":{"rendered":"<div class=\"wpb-content-wrapper\" id=\"wpb-content-root\"><p>[vc_row section_type=&#8221;container-width&#8221; padding_top_multiplier=&#8221;4x&#8221; padding_bottom_multiplier=&#8221;4x&#8221; rc_bg_type=&#8221;image&#8221; rc_bg_image=&#8221;594&#8243; rc_bg_image_size=&#8221;full&#8221; rc_bg_color_overlay=&#8221;black&#8221; columns_gap=&#8221;none&#8221; mobile_columns_vertical_gap=&#8221;none&#8221; rc_margin_bottom=&#8221;20px&#8221;][vc_column width=&#8221;5\/12&#8243; content_width=&#8221;custom&#8221; vertical_content_position=&#8221;bottom&#8221; rc_bg_type=&#8221;color&#8221; rc_add_shadow=&#8221;small-shadow&#8221; expand_column_bg=&#8221;expand-bg-left&#8221; tablet_width=&#8221;1-2&#8243; mobile_column_order=&#8221;2&#8243; mobile_expand_column_bg=&#8221;reset&#8221; grve_css=&#8221;{&#8220;desktop&#8220;:{&#8220;margin-top&#8220;:&#8220;5%&#8220;,&#8220;margin-bottom&#8220;:&#8220;5%&#8220;,&#8220;margin-left&#8220;:&#8220;-5%&#8220;,&#8220;border-top-right-radius&#8220;:&#8220;10px&#8220;,&#8220;border-bottom-right-radius&#8220;:&#8220;10px&#8220;,&#8220;padding-top&#8220;:&#8220;10%&#8220;,&#8220;padding-right&#8220;:&#8220;10%&#8220;,&#8220;padding-bottom&#8220;:&#8220;10%&#8220;,&#8220;class&#8220;:&#8220;grve-wpb-1737559463703&#8220;},&#8220;tablet_landscape&#8220;:{&#8220;margin-left&#8220;:&#8220;0&#8220;},&#8220;tablet_portrait&#8220;:{&#8220;margin-left&#8220;:&#8220;0&#8220;,&#8220;padding-left&#8220;:&#8220;10%&#8220;},&#8220;mobile_landscape&#8220;:{&#8220;margin-top&#8220;:&#8220;0&#8220;,&#8220;margin-right&#8220;:&#8220;10px&#8220;,&#8220;margin-bottom&#8220;:&#8220;-100px&#8220;,&#8220;margin-left&#8220;:&#8220;10px&#8220;,&#8220;border-top-left-radius&#8220;:&#8220;8px&#8220;,&#8220;border-top-right-radius&#8220;:&#8220;8px&#8220;,&#8220;border-bottom-right-radius&#8220;:&#8220;8px&#8220;,&#8220;border-bottom-left-radius&#8220;:&#8220;8px&#8220;,&#8220;padding-top&#8220;:&#8220;5%&#8220;,&#8220;padding-right&#8220;:&#8220;15px&#8220;,&#8220;padding-bottom&#8220;:&#8220;5%&#8220;,&#8220;padding-left&#8220;:&#8220;15px&#8220;}}&#8221; rc_bg_color=&#8221;#95C01E&#8221; custom_content_width=&#8221;400px&#8221;]<h1 class=\"grve-element grve-title grve-align-inherit grve-h4\"><span>Biocides in evaporative cooling systems<\/span><\/h1>[vc_column_text]Assessmenrt of the active ingredients used and recommendations for risk minimisation and procurement[\/vc_column_text][\/vc_column][vc_column width=&#8221;7\/12&#8243; tablet_width=&#8221;1-2&#8243; mobile_column_order=&#8221;1&#8243; grve_css=&#8221;{&#8220;desktop&#8220;:{&#8220;margin-bottom&#8220;:&#8220;0&#8220;,&#8220;class&#8220;:&#8220;grve-wpb-1737549085478&#8220;},&#8220;mobile_landscape&#8220;:{&#8220;margin-bottom&#8220;:&#8220;25px&#8220;}}&#8221;]<div style=\"height: 200px;\" class=\"grve-empty-space\"><\/div>[\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/4&#8243; text_align=&#8221;right&#8221; mobile_text_align=&#8221;left&#8221;]<h3 class=\"grve-element grve-title grve-align-inherit grve-h5 grve-with-line grve-bottom-line\"><span>Study commissioned by the Vienna Ombuds Office for Environmental Protection<\/span><span class=\"grve-title-line grve-bg-primary-1\" style=\"width: 50px;height: 2px;\"><\/span><\/h3>[\/vc_column][vc_column width=&#8221;3\/4&#8243;][vc_column_text]On behalf of the Vienna Ombuds Office for Environmental Protection, the Technisches B\u00fcro Klade investigated the use of biocides in evaporative cooling systems. The aim of the study was to assess the risks of the active ingredients used to human health and the environment and to derive recommendations for operation, procurement and risk minimisation.<\/p>\n<p>In open circuit cooling systems, biocides are used to prevent or at least limit the formation of biofilms and the proliferation of pathogenic microorganisms &#8211; especially Legionella. In addition, chemicals are often added to the cooling water to reduce deposits and corrosion.<\/p>\n<p>Legionella prefer to multiply at water temperatures between 25 \u00b0C and 45 \u00b0C and find favorable growth conditions in biofilms. In open cooling systems, they can be released as aerosols and inhaled by people in the area. Documented outbreaks of disease, some of which were fatal, illustrate the importance of professional maintenance and operational management.<\/p>\n<p>The study does not evaluate the effectiveness of the biocides examined against Legionella. This is required for the approved applications. Rather, the focus is on the hazardous properties of the active ingredients, their environmental behaviour and the burdens associated with their use.<\/p>\n<p>The following questions were examined in particular:<\/p>\n<ul>\n<li>What risks can the biocides used pose to human health and the aquatic environment?<\/li>\n<li>How important are the application conditions and the entry of the active ingredients into the wastewater?<\/li>\n<li>Which active ingredients and processes can be classified as comparatively favorable when considering the hazard potential, maintenance effort and operational requirements?<\/li>\n<li>What technical and organizational measures can be used to reduce the use of problematic biocides?<\/li>\n<\/ul>\n<p>The results show that, in addition to the selection of suitable active ingredients, the structural and technical condition, regular maintenance and professional management of the systems are crucial. By correcting technical deficiencies and effective system management, the need for biocides and other wastewater-related chemicals can be significantly reduced.<\/p>\n<p>Among the biocidal processes, oxidizing processes with the lowest possible formation of adsorbable organically bound halogens (AOX) appear to be comparatively advantageous. These include the on-site generation of active chlorine by electrolysis of a sodium chloride solution and the use of chlorine dioxide that is as pure as possible.<\/p>\n<p>Processes based on hydrogen peroxide, monochloramine or ozone can also fundamentally represent suitable alternatives. However, there is currently only limited practical experience in Austria for some of these procedures.<\/p>\n<p>With appropriate maintenance and operational management, the use of wastewater-relevant biocides and environmentally hazardous corrosion inhibitors can be reduced or avoided under certain conditions. The study advises against the use of the active ingredients CMIT\/MIT, DBNPA and glutaraldehyde, particularly due to their hazardous properties and for employee and environmental protection reasons.<\/p>\n<p>The following active ingredients, active ingredient groups and processes were examined in detail:<\/p>\n<ul>\n<li>Monochloramine<\/li>\n<li>Chlorine dioxide<\/li>\n<li>Active chlorine<\/li>\n<li>Active bromine<\/li>\n<li>BCDMH (bromochlorohydantoin)<\/li>\n<li>DBNPA (2,2-dibromo-2-cyanacetamide)<\/li>\n<li>Bronopol (2-bromo-2-nitropropane-1,3-diol)<\/li>\n<li>CMIT\/MIT<\/li>\n<li>Hydrogen peroxide, including combinations with silver<\/li>\n<li>ozone<\/li>\n<li>Peracetic acid<\/li>\n<li>Benzalkonium chlorides and other quaternary ammonium compounds (QACs)<\/li>\n<li>Glutaraldehyde<\/li>\n<li>other biocidal active ingredients and processes, including THPS and peroxomonosulfate<\/li>\n<\/ul>\n<p>The study combines the evaluation of the material properties with the operational conditions of the application. It thus offers a technical basis for selecting the lowest-risk processes possible and for the precautionary use of biocides in evaporative cooling systems.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/4&#8243; text_align=&#8221;right&#8221; mobile_text_align=&#8221;left&#8221;]<h3 class=\"grve-element grve-title grve-align-inherit grve-h5 grve-with-line grve-bottom-line\"><span>Download &amp; Links<\/span><span class=\"grve-title-line grve-bg-primary-1\" style=\"width: 50px;height: 2px;\"><\/span><\/h3>[\/vc_column][vc_column width=&#8221;3\/4&#8243;][vc_column_text el_class=&#8221;download&#8221;]<a href=\"https:\/\/www.tb-klade.at\/wp-content\/uploads\/2025\/09\/kuehlturmstudie-englisch-12092025.pdf\">Use of Biocides in Evaporative Cooling Systems &#8211; Risk Mitigation and Procurement Proposals (9\/2023)<\/a><br \/>\n<a href=\"https:\/\/wua-wien.at\/umwelt-und-gesundheit\/chemikalien-und-schadstoffe\/2494-biodzide-in-verdunstungskuehlanlagen\" target=\"_blank\" rel=\"noopener\">LINK: Vienna Environmental Ombudsperson: New study on biocides in evaporative cooling systems shows need for action (11\/2023)<\/a>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row section_type=&#8221;container-width&#8221; padding_top_multiplier=&#8221;4x&#8221; padding_bottom_multiplier=&#8221;4x&#8221; rc_bg_type=&#8221;image&#8221; rc_bg_image=&#8221;594&#8243; rc_bg_image_size=&#8221;full&#8221; rc_bg_color_overlay=&#8221;black&#8221; columns_gap=&#8221;none&#8221; mobile_columns_vertical_gap=&#8221;none&#8221; rc_margin_bottom=&#8221;20px&#8221;][vc_column width=&#8221;5\/12&#8243; content_width=&#8221;custom&#8221; vertical_content_position=&#8221;bottom&#8221; rc_bg_type=&#8221;color&#8221; rc_add_shadow=&#8221;small-shadow&#8221; expand_column_bg=&#8221;expand-bg-left&#8221; tablet_width=&#8221;1-2&#8243; mobile_column_order=&#8221;2&#8243; mobile_expand_column_bg=&#8221;reset&#8221; grve_css=&#8221;{&#8220;desktop&#8220;:{&#8220;margin-top&#8220;:&#8220;5%&#8220;,&#8220;margin-bottom&#8220;:&#8220;5%&#8220;,&#8220;margin-left&#8220;:&#8220;-5%&#8220;,&#8220;border-top-right-radius&#8220;:&#8220;10px&#8220;,&#8220;border-bottom-right-radius&#8220;:&#8220;10px&#8220;,&#8220;padding-top&#8220;:&#8220;10%&#8220;,&#8220;padding-right&#8220;:&#8220;10%&#8220;,&#8220;padding-bottom&#8220;:&#8220;10%&#8220;,&#8220;class&#8220;:&#8220;grve-wpb-1737559463703&#8220;},&#8220;tablet_landscape&#8220;:{&#8220;margin-left&#8220;:&#8220;0&#8220;},&#8220;tablet_portrait&#8220;:{&#8220;margin-left&#8220;:&#8220;0&#8220;,&#8220;padding-left&#8220;:&#8220;10%&#8220;},&#8220;mobile_landscape&#8220;:{&#8220;margin-top&#8220;:&#8220;0&#8220;,&#8220;margin-right&#8220;:&#8220;10px&#8220;,&#8220;margin-bottom&#8220;:&#8220;-100px&#8220;,&#8220;margin-left&#8220;:&#8220;10px&#8220;,&#8220;border-top-left-radius&#8220;:&#8220;8px&#8220;,&#8220;border-top-right-radius&#8220;:&#8220;8px&#8220;,&#8220;border-bottom-right-radius&#8220;:&#8220;8px&#8220;,&#8220;border-bottom-left-radius&#8220;:&#8220;8px&#8220;,&#8220;padding-top&#8220;:&#8220;5%&#8220;,&#8220;padding-right&#8220;:&#8220;15px&#8220;,&#8220;padding-bottom&#8220;:&#8220;5%&#8220;,&#8220;padding-left&#8220;:&#8220;15px&#8220;}}&#8221; rc_bg_color=&#8221;#95C01E&#8221; custom_content_width=&#8221;400px&#8221;][vc_column_text]Assessmenrt of the active ingredients used and recommendations for risk minimisation and procurement[\/vc_column_text][\/vc_column][vc_column width=&#8221;7\/12&#8243; tablet_width=&#8221;1-2&#8243; mobile_column_order=&#8221;1&#8243; grve_css=&#8221;{&#8220;desktop&#8220;:{&#8220;margin-bottom&#8220;:&#8220;0&#8220;,&#8220;class&#8220;:&#8220;grve-wpb-1737549085478&#8220;},&#8220;mobile_landscape&#8220;:{&#8220;margin-bottom&#8220;:&#8220;25px&#8220;}}&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/4&#8243; text_align=&#8221;right&#8221; mobile_text_align=&#8221;left&#8221;][\/vc_column][vc_column width=&#8221;3\/4&#8243;][vc_column_text]On behalf of the Vienna Ombuds Office for Environmental Protection, the Technisches B\u00fcro [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":282,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-707","page","type-page","status-publish","hentry","grve-entry-item"],"_links":{"self":[{"href":"https:\/\/www.tb-klade.at\/en\/wp-json\/wp\/v2\/pages\/707","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tb-klade.at\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.tb-klade.at\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.tb-klade.at\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tb-klade.at\/en\/wp-json\/wp\/v2\/comments?post=707"}],"version-history":[{"count":13,"href":"https:\/\/www.tb-klade.at\/en\/wp-json\/wp\/v2\/pages\/707\/revisions"}],"predecessor-version":[{"id":1109,"href":"https:\/\/www.tb-klade.at\/en\/wp-json\/wp\/v2\/pages\/707\/revisions\/1109"}],"up":[{"embeddable":true,"href":"https:\/\/www.tb-klade.at\/en\/wp-json\/wp\/v2\/pages\/282"}],"wp:attachment":[{"href":"https:\/\/www.tb-klade.at\/en\/wp-json\/wp\/v2\/media?parent=707"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}